Thermo King MAGNUM Plus Reefer Unit

Thermo King MAGNUM Plus Reefer Unit

Nationwide Delivery.

Thermo King MAGNUM Plus Reefer Unit
SKU
RWTKMP
Thermo King MAGNUM Plus Reefer Unit
SKU
RWTKMP
$12,900

Need a custom quote?

The all-electric, robust refrigeration unit, is perfect for both sea and land transport. Designed for the front wall of containers, it ensures optimal cooling and heating.
 

Have questions?

Schedule a call

 

Easy Install & Removal: Integrated forklift pockets.
Durable: Aluminum construction with corrosion resistance.
Accessible Maintenance: Front-accessible components, with a removable evaporator door.
Power Ready: Includes an 18.3m power cable for 460-380V/3 Ph/60-50 Hz.
Efficient Motors: Equipped with high-performance electric motors.
Automatic Phase Correction: Ensures smooth operation of fans and compressor.

MAGNUM+ Model — Air Cooled Condensing*

Return air to evaporator coil inlet

460/230V, 3 Phase, 60 Hz Power

Net Cooling Capacity

Power Consump

60 Hz Capacity B/hr

60 Hz Capacity kW

60 Hz Power kW

21.1 C (70 F)

56,700

16.603

11.55

1.7 C (35 F)

40,945

11.990

11.03

-17.8 C (0 F)

24,785

7.258

7.57

-29 C (-20 F)

17,215

5.041

6.6

-35 C (-31 F)

14,000

4.104

6.03

*System net cooling capacity with a 38 C (100 F) ambient air temperature and R-404A.

The all-electric, robust refrigeration unit, is perfect for both sea and land transport. Designed for the front wall of containers, it ensures optimal cooling and heating.
 

Have questions?

Schedule a call

 

Easy Install & Removal: Integrated forklift pockets.
Durable: Aluminum construction with corrosion resistance.
Accessible Maintenance: Front-accessible components, with a removable evaporator door.
Power Ready: Includes an 18.3m power cable for 460-380V/3 Ph/60-50 Hz.
Efficient Motors: Equipped with high-performance electric motors.
Automatic Phase Correction: Ensures smooth operation of fans and compressor.

MAGNUM+ Model — Air Cooled Condensing*

Return air to evaporator coil inlet

460/230V, 3 Phase, 60 Hz Power

Net Cooling Capacity

Power Consump

60 Hz Capacity B/hr

60 Hz Capacity kW

60 Hz Power kW

21.1 C (70 F)

56,700

16.603

11.55

1.7 C (35 F)

40,945

11.990

11.03

-17.8 C (0 F)

24,785

7.258

7.57

-29 C (-20 F)

17,215

5.041

6.6

-35 C (-31 F)

14,000

4.104

6.03

*System net cooling capacity with a 38 C (100 F) ambient air temperature and R-404A.